Sign In | Join Free | My enlightcorp.com
China Beijing Jinshengxin Testing Machine Co., Ltd. logo
Beijing Jinshengxin Testing Machine Co., Ltd.
Quality is the life of an enterprise.
Verified Supplier

8 Years

Home > Digital Hardness Tester >

USB Touch Screen Digital Rockwell Hardness Testing Machine With Menu Structure

Beijing Jinshengxin Testing Machine Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

USB Touch Screen Digital Rockwell Hardness Testing Machine With Menu Structure

  • 1
  • 2

Brand Name : JINHAIHU

Model Number : LHRS-150(Touch Screen)

Certification : ISO 9001

Place of Origin : CHINA

MOQ : 1 set

Payment Terms : L/C, D/A, D/P, T/T, MoneyGram, Western Union

Supply Ability : 20 sets per month

Delivery Time : 7 -15 days

Packaging Details : Standard wooden case

Product name : Digital Touch Screen Hardness Rockwell Tester With Menu Structure

Resolution : 0.1HR

Data output : Build-in Printer, USB

Preliminary Testing force : 10kgf(98.07N)

Duration time : 0~60S

Testing force : 60kgf(588N),100kgf(980N),150kgf(1471N)

Scale : HRA,HRB,HRC,HRD,HRF,HRG,HRH,HRSRK,HRL,HRM,HRR,HRP,HRS,HRV

Power supply : AC220V+5%,50-60Hz

Max Height of Specimen : 170mm

Distance of Indenter to outer wall : 165mm

Contact Now

Digital Touch Screen Hardness Rockwell Tester With Menu Structure


Digital Large Touch Screen Hardness Rockwell Tester With A Newly-Designed Displaying And The Menu Structure

The Rockwell Hardness Tester is equipped with a newly-designed large displaying and the menu structure equipped touch screen, easy operation and testing. The typical feature of present hardness tester is to test the hardness value reliably and accurately.
The errors of hardness values can be revised by pressing input keys; therefore, it enables the hardness values measured more precisely to meet the needs of test requirements.
The Technical Specifications:
♦ Initial test force: 98.07N (10Kg); Tolerance: ±2.0%
♦ Total test force: 588.4N (60Kg), 980.7N (100Kg), 1471N (150Kg), Tolerance: 1.0%
♦ Indenter specifications:
120°Diamond Rockwell Indenter
1/16 (φ1.5875mm) ball indenter
♦ Power supply voltage: AC220V ±5%, 50-60Hz
♦ Time delayed control: 1-60seconds adjustable
♦ The Max. Height of the Specimen: 170mm
♦ The Distance (Indenter to the Body): 165mm
♦ Dimension of the Tester: 520×240×720mm (length ×width× height).
♦ Approx Net Weight of the Tester: 80Kg
♦ The Scales, Indenters, Test Force and Application Fields of the Rockwell Hardness Tester (Table 1)
♦ The Tolerances of Display Value (The Commonly-Used Scale for the Rockwell Hardness Tester are scales A, B, C)

Technical Parameters:

Technical Parameters
Model LHRS-150(Touch Screen)
Resolution 0.1HR
Data output Build-in Printer, USB
Duration time 0-60s
Preliminary Testing force 10kgf(98.07N)
Testing force 60kgf(588N),100kgf(980N),150kgf(1471N)
Scale HRA,HRB,HRC,HRD,HRF,HRG,HRH,HRSRK,HRL,HRM,HRR,HRP,HRS,HRV
Max Height of Specimen 170mm
Distance of Indenter to outer wall 165mm
Power supply AC220V+5%,50-60Hz
Overall Dimension (mm) 520*240*700mm
Net weight About 80Kg

Accessories (The Packing List):
Name Quantity Name Quantity
Diamond Rockwell Indenter 1
φ1.5875mm Ball Indenter
1
Standard Block HRB
1
Testing Table (Big, Medium, “V”)
3
Standard Block HRC (High, low)
2
Fuse 2A
2
Regulating Screw
4
Power Cable
1
Printer paper
1
Weight A,B,C
3
Plastic Anti-dust Bag
1
Instruction Manual
1

Maintenance of the hardness tester and the precautions:
1, tester is rarely used, the several tests should be carried out to make the tester stable and then carry out the necessary tests.
2, During the hardness test, when the loading and unloading of the test force or the keep of the dwell time is being carried out, it is prohibited to turning the load changing hand wheel.
3, The hardness block should be used only on the working plane with the distance of the two neighboring indentations and of the center of the indentations to their edges are not inferior 3mm. The life time of the blocks is 2 years.
4, During the transportation of the tester, the tester should be fixed with long poles, with the weights and the hanging rod discharged. Disconnect the power source before the weights and the hanging rod are taken out.
5, Keep the tester clean and cover the tester after the use, lubricate the hardness blocks and ball indenters with the grease.
6, Carry out periodic control of the tester, at least once a year in order to assure the correct operation of the tester.
7, The treatment of the common malfunctions of the tester. When the test is in the un-working state, please contact after-sales services from the factory.
Pictures:

USB Touch Screen Digital Rockwell Hardness Testing Machine With Menu Structure


USB Touch Screen Digital Rockwell Hardness Testing Machine With Menu StructureUSB Touch Screen Digital Rockwell Hardness Testing Machine With Menu StructureUSB Touch Screen Digital Rockwell Hardness Testing Machine With Menu Structure


Product Tags:

usb digital rockwell hardness testing machine

      

touchscreen digital rockwell hardness testing machine

      

touch screen digital rockwell hardness tester

      
Quality USB Touch Screen Digital Rockwell Hardness Testing Machine With Menu Structure for sale

USB Touch Screen Digital Rockwell Hardness Testing Machine With Menu Structure Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Jinshengxin Testing Machine Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)